VLX-100E1: 4/8 Channel E1 DB15 / BNC Optical
Multiplexer Order Info: |
| VLX-100E1:
E1 Data Over Single Pair Fiber |
| Image |
Part No. |
Description |
Price |
|
VLX-100E1-4D |
4
Channel E1 DB15 Optical Multiplexer |
|
VLX-100E1-8D |
8
Channel E1 DB15 Optical Multiplexer |
|
VLX-100E1-4B |
4
Channel E1 BNC Optical Multiplexer |
|
VLX-100E1-8B |
8
Channel E1 BNC Optical Multiplexer |
|
|
Related Products |
VX-6009LRT
Long Reach Ethernet Switch
(Remote Side) |
WGSW-5240
48 Port 10/100 Mbps + 4G TP/SFP Combo Ethernet Switch
|
|
| VLX-100E1
4/8 Channel E1 DB15 / BNC Optical Multiplexer Description: |
VLX-100 4
/ 8 Channel E1 DB15 / BNC Optical Multiplexer Product
is designed to connect up to 8 channels of E1 data
over a pair of single mode or multimode fiber cable.
Because of its unique design, the optical multiplexer
can also be ordered with any combinations of E1
data channels. Each of the E1 channel is transmitted
on its own recovered clock, has its own line interface
unit that can be configured to match the connected
device, and has its individual buffer to remove
jitters.
To provide complete diagnostics, the VLX-100 optical
multiplexer offers 4 loopback modes for each individual
channel: local/ remote loopback at the Master, and
local/remote loopback at the Slave. The multiplexer
system continuously monitors the fiber signal as
well as each active channel, and reports alarms
as soon as they occur. Performance history, including
Errored second and Unavailable second, are recorded
individually for each channel. Back
to Top |
|
4/8 Channel E1 DB15 / BNC Optical Multiplexer
Features: |
| |
| Management
Features: |
| Managing
the VLX-100 can be done through either the
front panel display, or the management port
with a dumb ASC2 terminal. The front panel
display provides a quick and easy way for
installation setup and status monitoring.
The management port provides the complete
configuration and performance monitoring functions.
|
 |
Display
System Status:
Status includes system up time, link status,
and channel status |
 |
Display
Alarm History:
System alarms are "Fiber Error",
and "CPU Error". Channel alarms
are "Carrier Loss", and "Receiving
AIS". Alarm history includes first/ last
occurrence time, and number of occurrence. |
 |
Display
T1/E1 24-hour Performance History:
24-hour history includes Errored second (ES),
and unavailable seconds (UAS). It is recorded
in 15-minute interval for the last 24 hours.
|
 |
Display
T1/E1 7-day Performance History:
7-day history also includes Errored second
(ES), and unavailable seconds (UAS). It is
recorded in 24-hour interval for the last
7 days. |
 |
Set
System Configuration:
System configuration includes date/time, system
ID, password, operation mode, logon lockout
time, idle logoff time, and loopback time-out
time. |
 |
Set
Channel Configuration:
Channel configuration includes channel enabling,
local LBO, remote LBO, line code, and loopback
test. |
*All
configuration settings are stored in the
non-volatile storage, and are restored after
powered-up or reset.
Back
to Top |
|
|
4/8 Channel E1 DB15 / BNC Optical Multiplexer Specifications: |
|
| Management
Port |
Optical |
| Interface: |
RS-232 DCE |
Link
Margin: |
18 dBm multimode |
| 18dBm single mode laser |
| Connector: |
DB9 Female |
Connector: |
ST/FC |
| Date Rate: |
Asynchronous 9600 baud |
Physical |
| Channel |
Dimensions: |
17 (L)in x 8.5 (W)in x 1.75 (H)in |
| E1 Interface: |
E1 G.703 |
Weight: |
2 lbs |
| E1
Data Rate: |
2.0 Mbps
+/- 100ppm |
System |
| E1 Connector: |
DB-15 female, 100ohm
BNC 75 Ohm TX/RX |
Power Supply: |
110-220VAC (Optional) |
| 24-48VDC (Optional) |
| E1 Line Code: |
AMI/HDB3 |
Humidity: |
5% to 95% non-condensing |
| E1 Cable Length: |
0-605 Feet |
Temperature: |
0°C to 60°C - Operating |
| 10°C to 85°C - Storage |
Optical |
|
| Wave Length: |
820 nm/1300 nm multimode |
|
| 1300 nm single mode |
|
|
|
|
|